Ultracrete HF High Flow Precision Grout (Pallet Offer 56x 25Kg Bags)
If you are looking for a trade deal with a Best Price Guarantee on a high flow precision grout for bridge bearing works then look no further.
UltraCrete HF is a Department of Transport 2601 specification high flow precision grout, that is suitable for the infill of voids from 10-100mm, the product is a very dense low permeability material, which does not suffer damage from freeze/thaw conditions.
Ultracrete HF High Flow Grout can be pumped or poured and is ideal for use as a bridge bearing grout, as well as for securing stanchion base plates, machine beds and parapet legs. HF meet the strict demands of The Specification for Highway Works Clause 2601.
Ultracrete HF is non shrink, won’t corrode or stain and has a workability time of 60 minutes, it also sets in just 8 hours and can be opened to traffic in 24 hours.
For queries or to speak to a member of our team call ☎️ 0330 122 1025.
Technical information
- Workability: 60 minutes
- Set time: 8 hours
- Open to traffic: 24 hours
- Depth: 10mm – 100mm
- Non-shrink
- Will not corrode or stain
- 70N/mm² compressive strength at 28 days
- Approved for use on the London Underground and Overground
- Size: 25kg bag
- Pallet Deal: 56 x 25kg bags
If you would like a copy of the technical data sheet or the safety data, we'll be happy to send these over to you. Call ☎️ 0330 122 1025.
How to mix HF High Flow Precision Grout
Mixing is best achieved in a clean forced action grout mixer or by a slow speed drill fitted with a paddle attachment. Larger quantities will require a high shear vane mixer.
To achieve a flowable mix use up to 4.5 litres of water. A fluid mix will require up to 4.8 litres.
Instructions:
- Measure the amount of water into the mixer to provide the consistency required.
- Slowly add the contents of a full bag of Ultracrete HF powder to the water.
- Mix continuously for 5 minutes ensuring that a smooth even consistency is obtained.
- It is essential that machine mixing
capacity and labour available is adequate to enable the grouting operation to be carried out continuously. This may require the use of a holding tank with provision for gentle agitation, to maintain fluidity.